S-PAR
Function for S Parameters design
Version 2.1
These are some function that I use in my calcolus in RF design with
the HP48SX and since I think that even more ham are interested in microwave
band I've posted it.
Follow the description of the function present in the S directory,
some routine that can help you in S parameter design at high frequencies.
{MAG}- Maximum Available Gain:
IN: (1:)S11 (2:)S12 (3:)S21 (4:)S22
OUT: (1:)MAG
S parameters must be inserted in polar form referred to 50 ohm
Gain is given in dB.
{MSG}- Maximum Stable Gain:
IN: (1:)S12 (2:)S21 <<<<<< ATTENTION: this is the only function
that use only S12 and S21 ! >>>>>>>>
OUT: (1:)MAG
S parameters must be inserted in polar form referred to 50 ohm
Gain is given in dB.
{K}- Stability factor:
IN: (1:)S11 (2:)S12 (3:)S21 (4:)S22
OUT: (1:)K
K value is in the range from 0 to 1
{RHOIN}-Reflection coefficient at the input port when the output is matched:
IN: (1:)S11 (2:)S12 (3:)S21 (4:)S22
OUT: (1:)RHOIN
It gives the reflection coefficient that you see at input port when the
output port is matched, by the use of {->Z} function you can obtain the
input impedance to match whit the source.
{RHOUT}-Reflection coefficient at the output port when the input is matched:
IN: (1:)S11 (2:)S12 (3:)S21 (4:)S22
OUT: (1:)RHOUT
It gives the reflection coefficient that you see at output port when
the input port is matched, by the use of {->Z} function you can obtain
the output impedance to match whit the load.
{->Z}-From reflection coefficient to impedance (Z) (referred to {Z0})
IN: (1:)S11 or (1:)S22 or (1:)RHOIN or (1:)RHOUT
OUT: (1:)Z11 or (1:)Z22
It transform the polar value of S11 or S22 in the correspondent value
of impedance referred to Z0.
{Z->}-From impedance (Z) to reflection coefficient (referred to {Z0})
IN: (1:)Z11 or (1:)Z22
OUT: (1:)S11 or (1:)S22 or (1:)RHOIN or (1:)RHOUT
{Z0}-Reference impedance
Value used by {SZ} but useful to know during calculation; usually 50
ohm; can be used every value
Place the following dir under path HOME/......./RF/S in provision of new
program for Radio Frequencies design.
--------cut here------------------------------------------------
%%HP: T(3)A(D)F(.);
DIR
MSG
\<< SWAP / ABS
LOG 10 *
\>>
MAG
\<< 4 DUPN K EVAL
5 ROLLD \-> I R D O
\<< 1 I ABS SQ
+ O ABS SQ - O I *
D R * - ABS -
IF 0 >
THEN DUP SQ
1 - \v/ NEG +
ELSE DUP SQ
1 - \v/ +
END LOG 10
* R D MSG EVAL +
\>>
\>>
K
\<< 4 DUPN 4 ROLL
* 3 ROLLD * - ABS
SQ 1 + 5 ROLLD ABS
SQ NEG 4 ROLLD ABS
SWAP ABS * 2 * SWAP
ABS SQ NEG SWAP 4
ROLLD + + SWAP /
\>>
\GrIN
\<< \-> S11 S12 S21
S22
\<< 1 S11 ABS
SQ + S22 ABS SQ -
S11 S22 * S12 S21 *
- ABS SQ - S11 S22
CONJ S11 S22 * S12
S21 * - * - DUP ARG
3 ROLLD ABS DUP2 SQ
4 * NEG SWAP SQ + \v/
3 PICK
IF 0 >
THEN NEG
END 3 ROLL
+ SWAP 2 * / SWAP
DUP SIN i * SWAP
COS + *
\>>
\>>
\GrOUT
\<< \-> S11 S12 S21
S22
\<< 1 S22 ABS
SQ + S11 ABS SQ -
S11 S22 * S12 S21 *
- ABS SQ - S22 S11
CONJ S11 S22 * S12
S21 * - * - DUP ARG
3 ROLLD ABS DUP2 SQ
4 * NEG SWAP SQ + \v/
3 PICK
IF 0 >
THEN NEG
END 3 ROLL
+ SWAP 2 * / SWAP
DUP SIN i * SWAP
COS + *
\>>
\>>
\->Z
\<< DUP 1 + SWAP
1 - NEG / Z0 *
\>>
Z\->
\<< DUP Z0 - SWAP
Z0 + /
\>>
Z0 50
END
----------------------------------------------------------------
Send suggestions, comments, complaints to:
------------------------------------------------------------------------------
Lapo Pieri | INTERNET: lapo@iroe.iroe.fi.cnr.it
| Phone +39 55 4378512 (PABX-> 276)
Istituto per la |
Ricerca sulle Onde | Home address: via A. dei Corbizi 9
Elettromagnetiche (IROE) | 50127 FIRENZE
(Firenze) | ITALY
|
of the National | On air IK5NAX
Council of Research (CNR)|
------------------------------------------------------------------------------